A simple, fast, and environmental-friendly determination method of alachlor residue in corn was established using QuEChERS- HPLC equipped with UV detector. Samples were extracted by a little acetonitrile, purified by N- propyl ethylenediamine (PSA) and graphitized carbon black (GCB). The concentration of alachlor was detected by HPLC-UV. The analytical column was C18 (250 mm×4.6 mm×5.0 μm) and the mobile phase was acetonitrile mixed with water (70:30 V/V). With a significant linear relation (R2≥0.994) of standard samples measured by this method, the average recovery rates of different alachlor doses (0.2-10 mg/kg) were 96.7%-113.8% and RSD were 3.2%-15.3%. The limit of detection and the limit of quantitation were 0.015 mg/kg and 0.05 mg/kg respectively. The accuracy, sensitivity and precision of this method can meet the requirement of pesticide residue analysis.

Key words

QuEChERS; alachlor; corn; HPLC

Cite this article

Download Citations
QuEChERS-HPLC Residue Analysis Method of Alachlor in Corn. Chinese Agricultural Science Bulletin. 2014, 30(31): 295-299 https://doi.org/10.11924/j.issn.1000-6850.2014-1310

References

[1]华南农业大学主编.植物化学保护[M].北京:农业出版社, 1986:521.
[2]段劲生, 岳永德, 花日茂, 等.甲草胺在花生中的残留分析及其稳定性[J].农药, 2009, 48(9):664-666
[3]Li Z, Bai S S, Hou M Y, et al.Magnetic Graphene Nanoparticles for the Preconcentration of Chloroacetanilide Herbicides from Water Samples Prior to Determination by GC-ECD[J].Anal Lett, 2013, 46(6):1012-1024
[4]Zhao E C, Shan W L, Jiang S R, et al.Determination of the chloroacetanilide herbicides in waters using single-drop microextraction and gas chromatography[J].Microchem J, 2006, 83(2):105-110
[5]Dong M F, Ma Y Q, Zhao E C, et al.Using multiwalled carbon nanotubes as solid phase extraction adsorbents for determination of chloroacetanilide herbicides in water[J].Microchim Acta, 2009, 165(1-2):123-128
[6]Jose R M, Bienvenida G L, Juan F.G R,et alDetermination of organic priority pollutants in sewage treatment plant effluents by gas chromatography high-resolution mass spectrometry[J].Talanta, 2010, 82(4):1318-1324
[7]Rahman M M, Sharma H M, Park J H, et al.Determination of alachlor residues in pepper and pepper leaf using gas chromatography and confirmed via mass spectrometry with matrix protection[J].Biomed Chromatogr, 2013, 27(7):924-930
[8]Tahboub Y R, Zaater M F, Barri T A.Simultaneous identification and quantitation of selected organochlorine pesticide residues in honey by full-scan gas chromatography-mass spectrometry[J].Anal Chim Acta, 2006, 558(1-2):62-68
[9]dos Reis Souza M R, Moreira C O, de Lima T G, et al.Validation of a matrix solid phase dispersion (MSPD) technique for determination of pesticides in lyophilized eggs of the chicken Gallus gallus domesticus[J]. Microchem J, 2013, 110:395-401.[J].Microchem J, 2013, 110:395-401
[10]Goncalves C, Carvalho J J, Azenha M A, et al.Optimization of supercritical fluid extraction of pesticide residues in soil by means of central composite design and analysis by gas chromatography-tandem mass spectrometry[J].J Chromatogr A, 2006, 1110(1-2):6-14
[11]Saito M, Kozutsumi D, Kawasaki M, et al.Multiresidue method for pesticides and veterinary drugs in bovine milk using GCMS and LCMSMS[J].J Food Hyg Soc Jpn, 2008, 49(3):228-238
[12]Zanes Furlani R P, Marcilio K M, Leme F M, et al.Analysis of pesticide residues in sugarcane juice using QuEChERS sample preparation and gas chromatography with electron capture detection[J].Food Chem, 2011, 126(3):1283-1287
[13]Sinha S N, Vasudev K, Rao M V V.Quantification of organophosphate insecticides and herbicides in vegetable samples using the "Quick Easy Cheap Effective Rugged and Safe" (QuEChERS) method and a high-performance liquid chromatography-electrospray ionisation-mass spectrometry (LC-MSMS) technique[J].Food Chem, 2012, 132(3):1574-1584
[14]Pirsaheb M, Khodadadi T, Bonyadi Z, et al.Evaluation of pesticide residues 2,4-D,Atrazine and Alachlor concentration in drinking water well of Mahidasht district-Kermanshah,Iran,2010-2011[J].World Appl Sci J, 2013, 23(11):1530-1537
[15]Shamsipur M, Fattahi N, Pirsaheb M, et al.Simultaneous preconcentration and determination of 2,4-D,alachlor and atrazine in aqueous samples using dispersive liquid-liquid microextraction followed by high-performance liquid chromatography ultraviolet detection[J].J Sep Sci, 2012, 35(20):2718-2724
Share on Mendeley
PDF(721 KB)

Accesses

Citation

Detail

Sections
Recommended

/